HC2A-ICXXX - High Temperature Industrial Humidity Probe

HC2A-ICXXX - High Temperature Industrial Humidity Probe

The Rotronic industrial probe is especially suitable for high temperatures up to 200 °C and demanding industrial environments. It measures humidity and temperature and is compatible with the HF5, HF8 series measurement transmitters, HP32 and HP23 handheld devices and the HL-NT dataloggers.

Advantages of the industrial probe

  • Measures relative humidity and temperature
  • Wide temperature measurement range -100…200 °C
  • Outstanding accuracy
  • repeatability and long-term stability
  • Advanced probe housing and construction
  • Hot swappable, no calibration adjustment required due to the digital interface with Rotronic devices

Applications of the probe

  • Industrial Manufacturing
  • Drying processes
  • Climate chambers
  • Brick industry

Smart Electronics

  • Based on the Rotronic’s AirChip3000
  • Calculates the dew / frost point
  • Alarm generation
  • Saves adjustment data so that probes can be
  • interchanged without re-adjusting
  • Can be cable mount up to 5 m
  • Hot-swappable

Flexibility and Compatibility of the industrial probe

  • User scalable analog ouput signals (2x 0…1V)
  • Digital interface via UART
  • Rapidly interfaced with HygroClip2 compatible devices from Rotronic or for OEM applications
More Information
Power supply 3.3…5 VDC
Allowed wind speed 3.5 m/s, without filter
Operating range -100…200 °C / 0…100 %rh
Dimensions Ø15 x 100 mm / Ø15 x 250 mm / Ø15 x 400 mm / Ø15 x 550 mm / Ø15 x 700 mm
User information from Software HW4 (devicemanager)
Software Update With internet and HW4 software
Analogue outputs scaleable by the user Yes
Psychrometric calculations Dew or frost point
Temperature sensor PT100 1/3 DIN Class B
Humidity sensor Hygromer HT-1
Probe type Industrial probe
Long-term stability <1 %rh / year
Response time t 63 <15 sec.
Accuracy at 23 ±5 °C ±0.8 %rh / ±0.1 K
Accuracy w. adjustment profile "standard" at 23 °C / 10, 35, 80 %rh ± 0.8 %rh / ± 0.1 K
Measuring range -100...200 °C (short-term peak load) / 0...100 %rh
Type of output signals 2 x 0…1 VDC
Digital output signal (standard) UART
Filter cartridge depending on the application, order separately
Probe protection Filter carrier, brass nickel plated
Probe material PPS
Max. cable length Up to 5 m with passive cable. Up to 100 m with active cable.
Reverse voltage protection Mechanically in the connector
FDA/GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible
Service Interface UART
Analog output signal (standard) 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
Probe adjustment by software 1 Point & multipoint %rh & °C