Measuring instruments and accessories for meteorology
HC2A-S3A High-End METEOROLOGICAL PROBE
The HC2A-S3A probe is the meteorological probe with a white housing but with a different filter (Wire-mesh filter with 10 µm filter pore size suitable for meteorological applications). It measures relative humidity and temperature and calculates the dew/frost point and is designed for the use in Rotronic meteorological applications.
Features of the meteorological probe
- Accuracy: ±0.8 %rh, ±0.1 K, at 23 °C (10...30 °C)
- Range of application: -50…80 °C / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
Advantages
- Especially designed for the use in meteorological applications
- New humidity sensor HYGROMER HM1-SK
- Outstanding accuracy, repeatability and long-term stability
- Available with interchangeable sensor
- Hot swappable, no calibration adjustment required due to the digital interface with Rotronic devices
Smart Electronic
- Based on the Rotronic’s AirChip3000
- Calculates the dew / frost point
- Saves adjustment data so that probes can be interchanged without re-adjusting (Hot-swappable)
Flexibility and Compatibility
- User scalable analog analog ouput signals (2x 0…1V)1
- Digital interface via UART
- Compatible with Rotronic devices HF5, HF8 and HP32
Probe type | High-End Meteorological Probe |
---|---|
Humidity sensor | Hygromer HM1-SK |
Temperature sensor | PT100 1/3 DIN Class B |
Long-term stability | <1 %rh / year with clean air or similar (See also pollutant table in the catalogue) |
Accuracy w. adjustment profile "standard" | ±0.8 %RH / ±0.1 K, at 10...30 °C Adjustment at 23 °C and 10, 35, 80 and 90 %RH |
Reproducibility Airchip | <0.02 %rh / 0.01 K |
Response time t 63 | <15 sec. |
Power consumption | 3.3...5 VDC, Calibration @ 3.3 VDC / ~4.5 mA |
Dimensions | Ø15 x 108 mm |
Operating range | -50…80 °C / 0…100 %rh |
Allowed wind speed | Max. 50 m/s, with wire-mesh filter |
Exploitation software | ROTRONIC HW5 |
Psychrometric calculations | Dew or frost point |
Analogue outputs scaleable by the user | Yes |
Software Update | With internet and HW5 software |
User information | from Software HW5 (devicemanager) |
Type of output signals | 2 x 0…1 VDC |
Digital output signal (standard) | UART |
Service Interface | UART |
FDA/GAMP compatibility | FDA 21 CFR Part 11 and GAMP compatible |
Probe adjustment by software | 1 Point & multipoint %rh & °C |
Device Protection by password | Yes |
Analog output signal (standard) | 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C |
Communication interfaces | UART |
Reverse voltage protection | Mechanically in the connector |
Max. cable length | Up to 5 m with passive cable. Up to 100 m with active cable. |
Probe protection | Polycarbonate plastic cage, white |
Enclosure material | Polycarbonate |
Weight | 17 g |
Data Processing via HW5 | with interface cables |
Filter type | Wire mesh filter, 10 μm |