HygroFlex series
HygroFlex7 - HF7 - heavy duty transmitter
The HF7 transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %RH and -100 to 150°C (-148 to 302°F). The probe of the HF7 can survive exposure to temperature up to 200°C (392°F). Equipped with a metal enclosure and a metal probe, the HF7 can handle the toughest industrial environments.
The HF7 transmitter is available in different configurations and has extensive settings and functions that can be configured and enabled with the ROTRONIC HW4 software after connecting the HF7 to a PC.
Applications
Measures relative humidity, temperature and dew/frost point in industrial environments
and outdoors. For use in harsh conditions.
Features
• Accuracy: ±1.0 %rh / ±0.2 K at 23°C ±5 K
• Temperature limit at probe: max. -100…200 °C / 0…100 %rh
• Range of application electronics: -40..85 °C / 0…100 %rh; -10…60 °C with LCD
• Metal housing (aluminum diecast) and probe of stainless steel or PPS
• Various probe lengths available
• Use as simulator for system validation *
• Service interface
• Adjusted at 23 °C and 10, 35, 80 %rh
Probe type | Industrial metal probe |
---|---|
Humidity sensor | Hygromer IN-1 |
Temperature sensor | PT100 1/3 DIN Class B |
Long-term stability | <1 %rh / year |
Number of probe inputs | 1 |
Calibration / adjustment | with Software HW4 |
Accuracy at 23 ±5 °C | ±1.0 %rh / ±0.2 K |
Response time t 63 | <10 sec. |
Power consumption | 15...40 VDC / 12...28 VAC |
Initialisation time | Typically 1.9 sec. |
Operating range | -40..85 °C / 0…100 %rF |
Exploitation software | ROTRONIC HW4 |
Psychrometric calculations | Dew or frost point |
Software Update | With internet and HW4 software |
Data processing via HW4 | with interface cables |
Circuit type | 2 -Wire or 3/4-Wire |
Service Interface | Mini USB (UART) |
IP protection rating | IP67 |
Fire protection class | incombustible |
FDA/GAMP compatibility | FDA 21 CFR Part 11 and GAMP compatible |
Measuring range with integrated probe | -100…200 °C / 0…100 %rh |
Probe adjustment by software | Yes, with service cable |
Analog output signal (standard) | 2 x 0…1 V, 0…5 V, 0…10 V, 0(4)…20 mA |
Probe material | Stainless steel 1.4305 (V2A) |
Enclosure material | Aluminum die casting |
Cable connections | 1x M16x1.5 or ½ "conduit adapter |
Want to learn more about our products?
We will be pleased to personally advise you.
+65 6376 2107
sg.info@processsensing.com