RMS-ADC-L-R
RMS-ADC-L-R
The RMS-ADC-L-R is a data logger with two integrated analog-to-digital converters to which two sensors can be connected for high-precision analog measurement. The data logger stores 44,000 pairs of measured values and sends them to the RMS database via LAN.
Compatible with
- RMS-WEB On-Premise Software ≥ V1.3.0
- RMS-CLD SaaS solutions ≥ V1.3.0
Benefits
- 44,000 data point memory
- 2 analog sensor inputs
- Various scaling: 0...1/5/10V and 0/4...20mA
- ±0.03 % f.s. measurement range accuracy
- Conforms to FDA CFR 21 Part 11 / GAMP 5
Applications
- Control cabinets
- Update of brownfield projects
| Dimensions | 83 x 29 x 29 mm |
|---|---|
| Fire protection class | UL94-V0 |
| Measurement interval | 10 s to 15 min |
| Weight | 100 g |
| Housing | PC. ABS |
| Start-up time | < 10 s |
| Current consumption | < 160 mA |
| FDA / GAMP | FDA 21 CFR part 11 / GAMP5 |
| Evaluation software / Compatibility | ≥ V1.3.0 |
| Storage and transport conditions | -20…30 °C, non-condensing |
| Accuracy | ± 0.03 % full-scale |
| Storage capacity | 44,000 data points |
| Measurement range | 0...1 V, 0...5 V, 0...10 V, 0...20 mA and 4...20 mA |
| AC adapter requirements | 24 VDC ±10 %, 4 W minimum, > 5 W power-limited |
| Protocols | HTTP / Modbus TCP |
| Ethernet cable requirement | Min. Cat 5, SFTP, max. 30 m |
| IP protection class | IP20 |
| Number of measuring points | 1 or 2 analog inputs |
| Sensor power supply (Vex) | 24V / 80 mA max. |
| PoE | 802.3af-2003, Class 1 |
| Soldering material | Lead free / RoHS conformity |
| Temperature accuracy | ± 0.02 % full-scale / °C |
| Measuring resistance / Load | 25 kΩ at voltage input, 250 Ω at current input |
| Sensor quality | Detection of sensor interruption (open loop); Detection of overload; Detection of underload at 4...20 mA |
Want to learn more about our products?
We will be pleased to personally advise you.
+44 1293 571000
uk.rotronic.instruments@processsensing.com