湿度
HC2A-S3A High-End METEOROLOGICAL PROBE
The HC2A-S3A probe is the meteorological probe with a white housing but with a different filter (Wire-mesh filter with 10 µm filter pore size suitable for meteorological applications). It measures relative humidity and temperature and calculates the dew/frost point and is designed for the use in Rotronic meteorological applications.
Features of the meteorological probe
- Accuracy: ±0.8 %rh, ±0.1 K, at 23 °C (10...30 °C)
- Range of application: -50…80 °C / 0…100 %rh
- Digital interface (UART) and scalable analog outputs, 0…1 V
- Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
Advantages
- Especially designed for the use in meteorological applications
- New humidity sensor HYGROMER HM1-SK
- Outstanding accuracy, repeatability and long-term stability
- Available with interchangeable sensor
- Hot swappable, no calibration adjustment required due to the digital interface with Rotronic devices
Smart Electronic
- Based on the Rotronic’s AirChip3000
- Calculates the dew / frost point
- Saves adjustment data so that probes can be interchanged without re-adjusting (Hot-swappable)
Flexibility and Compatibility
- User scalable analog analog ouput signals (2x 0…1V)1
- Digital interface via UART
- Compatible with Rotronic devices HF5, HF8 and HP32
| 探头类型 | High-End Meteorological Probe |
|---|---|
| 传感器 | Hygromer HM1-SK |
| 温度传感器 | PT100 1/3 DIN Class B |
| 长期稳定性 | <1 %rh / year with clean air or similar (See also pollutant table in the catalogue) |
| 精度,标准精度模式 | ±0.8 %RH / ±0.1 K, at 10...30 °C Adjustment at 23 °C and 10, 35, 80 and 90 %RH |
| Airchip的重复性 | 0.02 %rh / 0.01 °C |
| 响应时间 t 63 | <15 sec. |
| 电源/功耗 | 3.3...5 VDC, Calibration @ 3.3 VDC / ~4.5 mA |
| 尺寸 | Ø15 x 108 mm |
| 工作范围 | -50…80 °C / 0…100 %rh |
| 最大风速 | Max. 50 m/s, with wire-mesh filter |
| 开发软件 | ROTRONIC HW5 |
| 计算量 | 露点或霜点 |
| 用户定义模拟输出 | 有 |
| Software Update | With internet and HW5 software |
| 用户信息 | from Software HW5 (devicemanager) |
| 输出信号类型 | 2 x 0…1 VDC |
| 数字输出信号(标准) | UART |
| 服务界面 | UART |
| FDA / GAMP兼容性 | 兼容FDA 21 CFR Part 11 和 GAMP |
| 通过软件调整探头 | 1点&多点%rh&°C |
| 设备通过密码保护 | 是 |
| 模拟输出信号(标准) | 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C |
| 通讯接口 | UART |
| 反向电压保护 | 机械连接 |
| 最大 电缆长度 | 无源电缆最长5m,有有源电缆最长100m |
| 探头保护 | 聚碳酸酯塑料套,白色 |
| 外壳材质 | 聚碳酸酯 |
| 重量 | 17 g |
| Data Processing via HW5 | with interface cables |
| 过滤器类型 | 丝网过滤器,10μm |